Mode setting, Specifications of the input/output, Input phase specifications of the external hd/vd – Sony XC-HR300 User Manual

Page 8

Advertising
background image

8

Mode Setting

Specifications of the Input/Output

Input Phase Specifications of the External HD/VD

100

100

100

472

472

0

Unit: Clock
1Clk=33.898 nsec

Make sure that the external HD/VD phases against the
standard central phase are as shown in the figure
above. Invalid signal input may cause an error in the
internal reset.
When you restart/reset the camera or operate the
camera by inputting an external trigger shutter pulse,
the Vsync signal for the image is output 1 H later from
the external VD.

External VD

External HD

EVEN,
Non Interlace

ODD

Mode Setting

Normal:

1N: Consecutively operated with 32

µ

s HD frequency

and 20 ms VD frequency. (See the above figure for
the phase timing).

2I: Consecutively operated with 32

µ

s HD frequency

and 10 ms VD frequency. (See the above figure
for the phase timing).

Restart/Restart and /External trigger shutter

Consecutively operated with 32

µ

s HD frequency. VD

(Reset) is on any timing as long as the HD phase
is within the range described above.

Advertising