4
Make sure the device you are using is compatible with a
modified sine wave inverter.
OPERATING INSTRUCTIONS
Connecting to a 12 volt Battery:
The PID-750 battery clamps allow quick hook-up to a
12V battery. Make sure the PID-750 and the device(s) are
turned OFF.
1. Unscrew the positive (red) and negative (black) plastic
connector knobs from the back of the inverter.
2. Slip the end of the red (positive) battery cable clamp
wire over the red (positive) threaded extension and then
screw on the connector knob and tighten so the wire is
firmly attached. Repeat the same process for the black
wire.
3. Connect the red (positive) battery cable to the positive
(+) battery terminal taking care to shield eyes, clothing
and hands from battery acid. Connect the black battery
clamp to negative (-) ground on the battery.
4. Plug the device into the Power Inverter 750 AC outlet.
NOTE: If using more than one device, the total combined
wattage of both devices must not exceed 750 watts.
5. To turn the inverter ON ( I ) or OFF ( 0 ), press and hold
button for 2 seconds. Turn the inverter ON.