Chapter 2
StorEdge A3500 Configurations
2-11
2.2
1x2 Cabling
The 1x2 can be configured with the controller module either on top of or below the
two disk arrays. Both configurations are described in this section.
2.2.1
SCSI Cabling
2.2.1.1
Cable Lengths
The following table shows the lengths of each SCSI cable connected to the drive
connections on the controller module.
The inboard IN/OUT connectors on each disk array are terminated with a
differential SCSI terminator, part number 150-1890-xx.
TABLE 2-5
Controller Module A (1x2)
SCSI Port Number
Cable Length
Part Number
1
.8m
530-1884-xx
2
.8m
530-1884-xx
3
.8m
530-1884-xx
4
.8m
530-1884-xx
5
Differential SCSI terminator
150-1890-xx