Electronic Appliance Checkout
To light the burner, refer to the lighting instruc-
tions on

page 14 and 15. Ensure the ignitor

lights the pilot. The pilot flame should engulf the
flame sensor as shown in

Figure 10

Figure 10

With proper care and maintenance, your appli-
ance will provide many years of enjoyment. If you
should experience any problem, first refer to the
trouble shooting guide in this manual. If problem
persists, contact your Lennox distributor.

WIRING DIAGRAMS

Wiring diagrams are provided here for refer-
ence purposes only. This information is also
provided on schematics attached directly to
the appliance on a pullout panel located within
the control compartment.

CAUTION: LABEL ALL WIRES PRIOR TO DIS-
CONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS APPLIANCE OPERATION.

WARRANTY

Your gas appliance is covered by a limited twenty
year warranty. You will find a copy of the war-
ranty accompanying this manual. Please read
the warranty to be familiar with its coverage.

REPLACEMENT PARTS

A complete parts list is found at the end of this
manual. Use only parts supplied from the
manufacturer.

Normally, all parts should be ordered through
your Lennox distributor or dealer. Parts will be
shipped at prevailing prices at time of order.

When ordering repair parts, always give the
following information:

PRODUCT REFERENCE INFORMATION

We recommend that you record the following important information about your fireplace. Please
contact your Lennox dealer for any questions or concerns. For the number of your nearest Lennox
dealer, please call 800-731-8101

Your Fireplace's Model Number _______________________________________

Your Fireplace's Serial Number ________________________________________

The Date On Which Your Fireplace Was Installed __________________________

The Type of Gas Your Fireplace Uses ___________________________________

Your Dealer's Name _________________________________________________

If you encounter any problems or have any
questions concerning the installation or appli-
cation of this system, please contact your dis-
tributor, or Lennox directly:

LHP

1110 West Taft Avenue • Orange, CA 92865

1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.

Retain this manual. File it with your other docu-
ments for future reference.

Proper Flame
Adjustment

Hot Surface
Igniter

Flame Rod

Ground
Electrode

3/8 To 1/2 Inch

(9 mm to 13 mm)

1. If any of the original wire as supplied must be replaced,

1.

it must be replaced with

Type AWM 105

°

C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

BK

Junction Box

Transf.

120 V.

24 V

Factory Wired

Field Wired

BL

Electronic Wiring Diagram (Honeywell)

Showing the Blower Wiring for the Optional

FBK-100 and FBK-200 Kits

R

W

BL

OPT

BLOWER

G

W

*OPTIONAL

ACCESSORY

SWITCH

120

VAC.

BK

W

Gas Valve

B

R

IGNITER

PILOT

ASSEMBLY

Break Off

Tab

BK

G

*Blower speed control switch is provided in FBK200 blower kit.

Outlet Box

Green Ground

Screw

Hot side of Outlet

Schematic Representation Only

**ON/OFF Switch (Integral

with Gas Valve)

**Leave the ON/OFF switch, which is integral

with the gas valve, in the ON position.

OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH

OR OPTIONAL WALL SWITCH

OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE RECEIVER

Red

pigtail

Black

pigtail

White Wire
to Opposite

Side

G

1. If any of the original wire as supplied must be replaced,

1.

it must be replaced with

Type AWM 105

°

C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

BK

Transf.

120 V.

24 V

Factory Wired

Field Wired

BL

Electronic Wiring Diagram (Honeywell)

Showing the Blower Wiring for the Optional

FBK-250 Kits

R

WH

BL

OPT

BLOWER

G

W

120

VAC.

BK

W

Gas Valve

B

R

IGNITER

PILOT

ASSEMBLY

BK

G

Outlet Box Green

Ground Screw

Hot side of Outlet

Schematic Representation Only

*ON/OFF Switch (Integral

with Gas Valve)

White Wire

To Opposite

Side

Optional FBK-250

Module

*Leave the ON/OFF switch, which is integral

with the gas valve, in the ON position.

G

OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH

OR OPTIONAL WALL SWITCH

OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE RECEIVER

Millivolt Wiring Diagram

If any of the original wire as supplied must be replaced,
it must be replaced with

Type AWM 105

°

C, 18 GA. wire.

Thermopile

TH

TP

TH

TP

*TWIST WIRES “A” AND “B” TOGETHER TO OPERATE UNIT

SOLELY BY MANIPULATING THE GAS VALVE CONTROL KNOB;
OR CONNECT WIRES TO OPTIONAL UNIT-MOUNTED ON/OFF

SWITCH OR WALL-MOUNTED ON/OFF SWITCH OR

THERMOSTAT TO OPERATE UNIT.

*UNIT-MOUNTED ON/OFF SWITCH (Accessory Option)

OR WALL-MOUNTED ON/OFF SWITCH (Accessory Option)

OR THERMOSTAT (Accessory Option)

OR REMOTE CONTROL RECEIVER (Accessory Option)

A

B