Other useful utilities, Cfgadm – Sun Microsystems PCI User Manual

Page 46

Advertising
background image

26

Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005

If an InfiniBand software package is not installed, check your Solaris Operating
System documentation for software package information.

■

Check the system log or console for Tavor driver error messages.

See tavor(7D) for error messages and descriptions. When the driver is attached
to a port on the adapter, the following message is sent.

In the message, n is the instance of the Tavor device number and m is the port
number on the adapter.

One way to check Tavor messages is by typing the following command:

Other Useful Utilities

These utilities can display status and other information about InfiniBand devices:

■

cfgadm

■

snoop

■

netstat

■

kstat

cfgadm

The cfgadm utility displays status and other information about the IB-HCA and
IB fabric. See cfgadm_ib(1M) for details. For example:

tavor

n: port m up (link width 4x).

# dmesg | grep tavor

# cfgadm -al

Ap_Id

Type

Receptacle

Occupant

Condition

hca:21346543210a987 IB-HCA connected configured ok

ib IB-FABRIC connected configured ok

ib::80020123456789a IB-IOC connected configured ok

ib::802abc9876543 IB-IOC connected unconfigured unknown

ib::80245678,ffff,ipib IB-VPPA connected configured ok

ib::12245678,0,nfs IB-PORT connected configured ok

ib::21346543,0,hnfs IB-HCA_SVC connected configured ok

ib::sdp,0 IB-PSEUDO connected configured ok

Advertising