Caution – Superior MILLIVOLT SDVST-N-B User Manual

Page 26

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

26

Step 4. FIELD WIRING

Note: The gas valve is set in place and pre-wired

at the factory.

A. SIT and Honeywell Millivolt Wiring

(See Figure 44)

1. Select any of the following optional controls:

wall-mounted switch, wall thermostat or

remote control kit. If appliance-mounted

ON/OFF control is selected mount it in the

gas valve mounting bracket.

2. If wall-mounted ON/OFF control or ther-

mostat is selected mount it in a convenient

location on a wall near the fireplace.

3. Wire the control within the millivolt control

circuit using the 15 feet of 2 conductor wire

supplied with the unit . Caution: Do NOT

connect the optional wall switch to a 120V

power supply.

4. Alternatively, the appliance may be operated

without the use of the controls indicated in

Step 1, solely by manipulating the gas valve

control knob. In order to use this method,

twist the free ends of the two conductor wire

(which would otherwise go to an Optional

Control Switch) together as shown in Figure

44.

Note: Wire is located inside the control

compartment.

Note: The supplied 15 feet of 2 conductor wire

has one end of each conductor connected to

the gas valve circuit and the other end of each

conductor placed loose inside the control

compartment.

Figure 45 -

Blower Wiring Diagram

Figure 44 -

Millivolt Wiring Diagram

Field Wired

Factory

Wired

TH

TP

TH

TP

u

Optional

Control Switch

Thermopile

Schematic
Representation
Only

• If any of the original wire as supplied must be replaced, it must be replaced with Type AWM

105 C - 18 gage wire.

u

Optional Kits Installed - ON/OFF wall switch, wall thermostat or remote control receiver.

HT

PT

HT

PT

*

u

Twist wires together to operate

unit solely by manipulating the gas

valve control knob; or connect wires

to optional wall thermostat, wall

switch or remote control to operate

unit.

1. If any of the original wire as supplied must be replaced,

1.

it must be replaced with Type AWM 105

°

C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

Wiring Diagram

Showing the Blower Wiring

for the Optional FBK-100 Kit

Factory Wired

Field Wired

Schematic Representation Only

Junction Box

Tab Intact

Tab

Broken

Plug blower

into this

receptacle

n

e

e

r

G

-

d

n

u

o

r

G

*Optional Accessory Switch

Optional

Blower

Ground

e

ti

h

W

-

l

a

rt

u

e

N

120 VAC - Black

Green

Ground

Screw

White

Green

Neutral

Side of

Receptacle

Hot

Side of

Receptacle

Red

Black

*J-BOX WIRING FOR

OPTIONAL (BLOWER

CONTROL) ACCESSORY

SWITCH

u

CAUTION: Label all wires prior to disconnec-

tion when servicing controls. Wiring errors can

cause improper and dangerous operation.

ATTENTION: Au moment de l'entretien des

commandes, étiquetez tous les fils avant de

les débrancher. Des erreurs de cáblage peu-

vent entraîner un fonctionnement inadéquat

et dangereux.

Verify proper operation after servicing.

S'assurer que l'appareil fonctionne adé-

quatement une fois l'entretien terminé.

CAUTION

Ground supply lead must be con-

nected to the wire attached to the

green ground screw located on the

outlet box. See Figure 45. Failure to

do so will result in a potential safety

hazard. The appliance must be

electrically grounded in accordance

with local codes or, in the absence of

local codes, the National Electrical

Code, ANSI/NFPA 70-latest edition.

(In Canada, the current CSA C22-1

Canadian Electrical Code).

Figure 46

Outlet Receptacle

Junction Box

Field-provided Metal Junction Box

Cover Plate With Screw

View Of Right

Bottom Corner Of Unit

Receptacle, Junction Box

and Cover Plate Installation

Fireplace

Side

Junction Box

knock-out (2

places each side)

Valve Access Side

Press snap

bushing into the

knock-out for

control switch

wires.