38

SIT Millivolt Gas Valve

Pilot for SIT Millivolt

Gas Valve

Figure 61

Pressure

Regulator

Remove

These

Components

Figure 60

Pilot
Orifice

NOTE: Flame appearance will diminish 4% per

thousand feet.

NOTE: Each model has two burners and 2

Orifices.

Burner Orifice Sizes

Elevation 0-4500 feet ( 0-1372 meters)

Elevation

Feet (meters)

Natural Gas

drill size (inches)

Propane

Gas

drill size (inches)

0-4500

(0-1372)

#44 (.086") *

60J80 •

#55 (.052")**

19L52 •

Table 9

Figure 63

BURNER POSITIONING

REAR BURNER

FRONT BURNER

PILOT

BURNER

Note: The burners are not identical. Position them so

that the circular burner ports run as shown. Note

especially the vertical run of ports relative to the pilot

burner. Bracket A on the rear burner will interfere with

the pilot burner if an attempt is made to install the

rear burner in the front burner’s position.

BRACKET A

BURNER

PORTS

NOTE: INSTALL REAR BURNER FIRST,

THEN FRONT BURNER.

Step 8. Reassemble the remaining components

by reversing the procedures outlined in the

preceding steps.

Step 9. Attach the conversion label provided

in the conversion kit to the rating plate on the

appliance.

Step 10. Turn on gas supply and test for gas

leaks. See Test All Connections For Gas Leaks

on Page 29.

Step 11. Attach manometer to the manifold

side pressure test fitting and verify manifold

pressure reads 3.5 inches water column (0.87

kPa) for natural gas, and 10.0 inches water

column (2.49 kPa) for propane gas.

ALWAYS TEST PRESSURES WITH THE VALVE

REGULATOR CONTROL AT THE HIGHEST

SETTING.

Step 6. See Figure 61 and remove the pilot
hood assembly to access the hexed pilot orifice.
Remove and replace the orifice with the one
provided with the kit.

Figure 62

BURNER

ORIFICE

Step 7. (Refer to Figure 59 on Page 37 and

Figure 62)

VERIFY THE PROPER ORIFICE SIZES

BEFORE INSTALLING THEM.

A. Remove the two orifices from the manifold

and replace them with the ones provided in the

kit. Table 9 shows the orifice sizes for natural

and propane models. Figure 62 illustrates the

orifice. Use pipe joint compound or Teflon tape

on all pipe fittings before installing (ensure

propane resistant compounds are used in

propane applications, do not use pipe joint

compounds on flare fittings).

B. Install rear burner first, followed by front

burner, as shown in Figure 63. Ensure that the

arm of the venturi of each burner is hooked onto

the air shutter adjustment lever (refer to Figure

59 on Page 37). The primary air opening can

be adjusted by rotating the adjustment lever

from beneath the firebox floor. Refer to Figure

56 on Page 32 for the recommended minimum

primary air opening setting.

* Standard size installed at factory

** Standard size in LP conversion kit

• Part /Cat. Number