Electrical connection, Instruction for the installer – Smeg JGFC34SKB User Manual

Page 7

Advertising
background image

Instruction for the installer

7

2.1 Electrical

connection

Make sure that the power line voltage matches the specifications indicated on the rating plate located

inside the storage compartment.
This rating plate must never be removed.

If the appliance is hooked-up to the supply by means of a fixed connection, install a multipolar cut-out

device on the line, with contact opening distance equal to or greater than 3 mm, located near the
appliance and in an easily reachable position.

Hook-up to the supply may be fixed or with plug and socket. In the latter case the plug and socket

must be suitable for the cable employed and conform with the regulations in force. Regardless of the
type of connection, earthing of the appliance is absolutely obligatory. Before connection make sure
that the supply line is suitably earthed. Avoid the use of reducers, adapters or shunts.1

If the power cable is replaced, the wire section on the new cable must

not be less than 1.5 mm

2

(3 x 1.5 cable), keeping in mind that the end to

be connected to the hob must have the ground wire (yellow-green)
longer by at least 20 mm. Use only H05V2V2-F cable or similar which has
a maximum temperature of 90°C. This must be done by a specialised
technician, who must connect the cooker to the electricity supply
according to the diagram shown here.
L = brown
N = blue

= yellow-green.

Advertising