Sony HDCU-900 User Manual

Page 66

Advertising
background image

3-22 (E)

HDCU-900 MM

1. Input Level Adjustment

Adjustment Procedure

Measuring point : TP405 (G-4)/IF-789A/789P
Adjusting point :

1RV401 (G-4)/IF-789A/789P

Specifications :

A = 1.56

±0.02 V p-p

2. Phase Adjustment

Adjustment Procedure

Measuring point : TP503 (G-1)/IF-789A/789P
Adjusting point :

1RV404 (L-3)/IF-789A/789P

Specifications :

B = 0

3. Return Level Adjustment (Y)

Adjustment Procedure

1.

CONFIG button/MSU

→ ON

Set using MSU on the touch panel as follows.
[CCU] → [RET|SETTING] → RET1 : 2nd Slot (DIF-RET-1)

2.

Measuring point : TP37/extension board (VDA-55)

Measure level C. (about 1400 mV)

3.

CONFIG button/MSU

→ ON

Set using MSU on the touch panel as follows.
[CCU] → [RET|SETTING] → RET1 : 3rd Slot (VDA-RET-1)

4.

Measuring point : TP37/extension board (VDA-55)
Adjusting point :

1RV402 (H-4)/IF-789A/789P

Specifications :

D = C

5.

Measuring point : TP37/extension board (VDA-55)
Adjusting point :

1RV501 (G-2)/IF-789A/789P

Specifications :

E = 0

6.

Repeat steps 4 and 5 until the specifications are
satisfied.

[for CE]

[for UC]

A

A

B

B

[for CE]

[for UC]

B

E

C, D

3-5. SD Signal System Adjustment (HKCU-901)