3-2-5. Side Tone Level Adjustment

Measures : Oscilloscope, Audio oscillator

Note

This adjustment is described on the premise that the output
impedance of the audio oscillator is 600

Z.

Preparation

. MIC switch/HDCU front panel → CARBON
. Board extension : AT-141 board (front side)

Adjustment Procedure

1.

Connect the audio oscillator and the INTERCOM
connector on the HDCU front panel as shown in the
following figure and input a sine wave of 1 kHz, 220
mV p-p (

_20 dBu).

2.

Adjust the output level of the audio oscillator so that a
sine wave of 1 kHz, 200 mV p-p appears on TP503
(M-4) on the AT-141 board.

3.

Measuring points : TP504 (M-4)/AT-141
Adjusting point :

1RV502 (SIDE TONE)/AT-141
board panel side

Specifications :

A = 20

±2 mV p-p

n
These specifications are set for service. When using this
unit, adjust the level to suit the user.

AT-141 board (A side and panel side)

DYNAMIC

OFF

CARBON

INTERCOM

CAMERA

MIC

POWER

POWER

MAIN

CAMERA

MAIN

RED TALLY

GREEN TALLY

CABLE

ALARM

SHORT

OPEN

MIC switch

INTERCOM connector

220

uF

(16 V or more)

600

Z

GND

1

2

3

4

5

+

Audio generator

A

S404

TP405

TP502

TP402

TP613

TP608

TP401

S504

S603

S126

S602

S601

R

V501

R

V502

R

V506

R

V505

R

V405

S503

TP503

TP504

S41

S403

S128

1

1

1

1

1 1

1

A

B

C

D

E

F

G

H

J

K

L

M

1

2

3

4

5

6

7

8

9

AT

POWER

/1.001

FINE

HD BB

REMOTE LOCAL

REFERENCE H PHASE

MIC LEVEL

REF

IN

GEN

LOCK

NORM

MIN

MIN

1

2

ENG PROD

PRIVATE

NORM

INCOM

SELECT

TALK

LEVEL

PGM

MIX

SIDE

TONE

2 WIRE

CANCEL

CH-1

CH-2

CCU

S401

S402

RV402

1

RV604

1

RV603

1

RV605

1

RV602

RV401

S102

S110

S101

3-2. Audio System Adjustment

Advertising
This manual is related to the following products: