3. video and reference signal system adjustment, 3-1. hd-sdi output vco free-run adjustment, 3-2. clock (74 mhz) duty adjustment/at board – Sony HDCU-900 User Manual

Page 53

Advertising
background image

3-9 (E)

HDCU-900 MM

3-3. Video and Reference Signal System

Adjustment

3-3-1. HD-SDI Output VCO Free-run

Adjustment

Measure : Frequency counter

Preparation

. Board extension: AT-141 board (front side)
. Remove the cable connected to the REFERENCE IN

connector on the HDCU rear panel.

. S603 (L-6)/AT-141 →/1000
. S601 (REMOTE/LOCAL)/AT-141 board panel side →

LOCAL

. S602 (REFERENCE)/AT-141 board panel side → HD
. S102-8 (K-6)/AT-141 → OFF
. Connect the measure as shown in the following figure.
. After turning on the power, wait for 10 minutes at least

and start adjustment.

Adjustment Procedure

1.

HD (60) frequency adjustment
Measuring point : TP613 (B-7)/AT-141
Adjusting point :

1RV604 (D-5)/AT-141

Specifications :

74,250,000

±10 Hz

2.

S603 (L-6)/AT-141

→ /1001

3.

HD (59.94) frequency adjustment
Measuring point : TP613 (B-7)/AT-141
Adjusting point :

1RV603 (D-5)/AT-141

Specifications :

74,175,750

±10 Hz

4.

S602 (REFERENCE)/AT-141 board panel side

→ BB

5.

SD frequency adjustment
Measuring point : TP608 (B-8)/AT-141
Adjusting point :

1RV602 (E-9)/AT-141

Specifications :

27,000,000

±10 Hz

Probe

Oscilloscope

Frequency
counter

CH2

IN

CH2

OUT

IN

3-3. Video and Reference Signal System Adjustment

Setting after Adjustment

After finishing the adjustment, return the switches to the
original setting.

3-3-2. Clock (74 MHz) Duty Adjustment/AT

Board

Measure : Oscilloscope (20 MHz BWLimit: ON)

Adjustment Procedure

Measuring point : TP613 (B-7)/AT-141
Adjusting point :

1RV605 (E-6)/AT-141

Specifications :

C = 1.65

±0.04 Vdc

When this adjustment is completed, perform “3-3-3. Clock
(74 MHz) Duty Adjustment/DPR Board”.

A

B

A

=B

C

GND

Advertising
This manual is related to the following products: