3-3. clock (74 mhz) duty adjustment/dpr board, 3-4. prompter level adjustment – Sony HDCU-900 User Manual

Page 54

Advertising
background image

3-10 (E)

HDCU-900 MM

3-3-3. Clock (74 MHz) Duty Adjustment/DPR

Board

Perform “3-3-2. Clock (74MHz) Duty Adjustment/AT
Board” before starting this adjustment.

Measure : Oscilloscope (20 MHz BWLimit: ON)

Note

This adjustment corresponds to the DPR-163 board with
part No. suffix -14.

Adjustment Procedure

Measuring point : TP307 (F-8)/DPR-163
Adjusting point :

1RV301 (F-9)/DPR-163

Specifications :

C = 1.65

±0.04 Vdc

A

B

A

=B

C

GND

3-3-4. Prompter Level Adjustment

Measures : SD waveform monitor

SD signal generator

Preparation

Connect the SD signal generator (for UC : SMPTE color
bar/for CE : EBU color bar) to the PROMPTER IN
connector/SDI-54A/SDI-82.

Adjustment Procedure

Measuring point : PROMPTER connector/CAMERA side
Adjusting point :

1RV501 (C-5)/DPR-163

Specifications :

A = 140

±1 IRE

(terminated at 75

Z) (for UC)

A = 1000

±7 mV p-p

(terminated at 75

Z) (for CE)

DPR-163 board (A side)

[for CE]

[for UC]

A

A

3-3. Video and Reference Signal System Adjustment

RV501

A

B

C

D

E

F

G

H

J

K

L

M

1

2

3

4

5

6

7

8

9

1

RV301

1

TP307

Suffix : -14

Advertising