3-11 (E)

HDCU-900 MM

3-4. Video Signal System Adjustment

(RC-86 Board)

3-4-1. SD-SDI Output VCO Adjustment

Measure : Frequency counter

Note

After replacing IC508 or IC510 on the RC-86 board only,
perform this adjustment.

Preparation

. Board extension : RC-86 board (front side)
. COR501 (B-8)/RC-86 → FREE RUN (Short between 2-

pin and 3-pin.)

. Connect the measure as shown in the following figure.
. After turning on the power, wait for 10 minutes at least

and start adjustment.

Probe

Oscilloscope

Frequency
counter

CH2

IN

CH2

OUT

IN

Adjustment Procedure

1.

Measuring point : TP501 (A-7)/RC-86
Adjusting point :

1RV501 (A-7)/RC-86

Specifications :

27.0

±0.2 MHz

2.

Measuring point : TP502 (A-8)/RC-86
Adjusting point :

1RV502 (A-8)/RC-86

Specifications :

27.0

±0.2 MHz

Note
After finishing the adjustment and waiting for 10 minutes
at least, confirm that each specification is satisfied.
If the specifications are not satisfied, perform the adjust-
ment again.

Setting after Adjustment

COR501 (B-8)/RC-86

→ NORMAL

(Short between 1-pin and 2-pin.)

A

B

C

D

E

F

G

H

J

K

L

M

1

2

3

4

5

6

7

8

9

S803

S801

S802

S811

1

1

R

V353

R

V350

R

V352

1

TP603

TP352

R

V601

COR601

TP350

1

TP501

R

V501

1

TP502

R

V502

COR501

1

TP201

RV201

TP703

RV701

Suffix:14

_

Suffix:14

_

1

1

RC-86 board (A side)

3-4. Video Signal System Adjustment (RC-86 Board)

Advertising
This manual is related to the following products: