4-3. main clock (74 mhz) duty adjustment, 4-4. return clock (74 mhz) duty adjustment, 13 (e) – Sony HDCU-900 User Manual

Page 57

Advertising
background image

3-13 (E)

HDCU-900 MM

3-4. Video Signal System Adjustment (RC-86 Board)

3-4-3. Main Clock (74 MHz) Duty Adjustment

Measure : Oscilloscope (20 MHz BWLimit: ON)

Note

This adjustment corresponds to the RC-86 board with part
No. suffix -14.

Preparation

. Board extension : RC-86 board (front side)

Adjustment Procedure

Measuring point : TP201 (C-6)/RC-86
Adjusting point :

1RV201 (C-6)/RC-86

Specifications :

C = 1.65

±0.04 Vdc

A

B

A

=B

C

GND

RC-86 board (A side)

3-4-4. Return Clock (74 MHz) Duty

Adjustment

Measure : Oscilloscope (20 MHz BWLimit: ON)

Note

This adjustment corresponds to the RC-86 board with part
No. suffix -14.

Preparation

. Board extension : RC-86 board (front side)

Adjustment Procedure

Measuring point : TP703 (B-2)/RC-86
Adjusting point :

1RV701 (B-2)/RC-86

Specifications :

C = 1.65

±0.04 Vdc

A

B

A

=B

C

GND

A

B

C

D

E

F

G

H

J

K

L

M

1

2

3

4

5

6

7

8

9

S803

RV351

RV354

S801

S802

S811

1

1

R

V353

R

V350

R

V352

1

1

TP603

TP352

R

V601

COR601

TP350

TP351

1

TP501

R

V501

1

TP502

R

V502

COR501

TP201

RV201

1

TP703

RV701

1

Suffix:14

_

Suffix:14

_

1

1

Advertising
This manual is related to the following products: