5-4. grb output level adjustment – Sony HDCU-900 User Manual

Page 63

Advertising
background image

3-19 (E)

HDCU-900 MM

3-5-4. GRB Output Level Adjustment

Measure : SD waveform monitor

Preparation

Board extension : VDA-57 board (rear side)

Adjustment Procedure

1.

G signal level adjustment-1
Measuring point : TP205 (D-8)/IF-789A/789P
Adjusting point :

1RV216 (D-7)/IF-789A/789P

Specifications :

A = 1000

±5 mV p-p

(terminated at 75

Z) (100% color bar)

2.

G signal level adjustment-2
Measuring point : Y/G OUTPUT connector/VDA-57
Adjusting point :

1RV64 (H-5)/VDA-57

Specifications :

B = 700

±5 mV

(terminated at 75

Z)

3.

R signal level adjustment-1
Measuring point : TP207 (D-7)/IF-789A/789P
Adjusting point :

1RV215 (D-7)/IF-789A/789P

Specifications :

C = 1000

±5 mV p-p

(100% color bar)

4.

R signal level adjustment-2
Measuring point : R-Y/R OUTPUT connector/VDA-57
Adjusting point :

1RV65 (K-5)/VDA-57

Specifications :

D = 700

±5 mV p-p

(terminated at 75

Z)

5.

B signal level adjustment-1
Measuring point : TP206 (D-8)/IF-789A/789P
Adjusting point :

1RV214 (D-8)/IF-789A/789P

Specifications :

E = 1000

±5 mV p-p

(100% color bar)

6.

B signal level adjustment-2
Measuring point : B-Y/B OUTPUT connector/VDA-57
Adjusting point :

1RV66 (J-5)/VDA-57

Specifications :

F = 700

±5 mV p-p

(terminated at 75

Z)

C, D

E, F

3-5. SD Signal System Adjustment (HKCU-901)