3-25 (E)

HDCU-900 MM

3-6. HD Signal Input/Output Adjustment (HKCU-902)

3-6-2. GBR Output Level Adjustment

Measure : HD waveform monitor

Preparation

. The Y/P

B

/P

R

output level adjustment (section 3-6-1)

should be completed.

. Board extension : ADA-59 board (rear side)
. S1 (F-2)/ADA-59 → 8
. BARS button/MSU → ON

Adjustment Procedure

1.

G mix level adjustment
Measuring point : Y/G OUTPUT1 connector/

ADA-59

Adjusting point :

1RV102 (J-4)/ADA-59
1RV103 (J-4)/ADA-59

Specifications :

Portion A and portion B must be
flat (within 5 mV).

2.

G signal level adjustment
Measuring point : Y/G OUTPUT1 connector/ADA-59
Adjusting point :

1RV104 (K-4)/ADA-59

Specifications :

C = 700

±5 mV

(terminated at 75

Z)

3.

B mix level adjustment
Measuring point : P

B

/B OUTPUT1 connector/ADA-

59

Adjusting point :

1RV202 (K-4)/ADA-59

Specifications :

Portion D and portion E must be
flat (within 5 mV).

4.

B signal level adjustment
Measuring point : P

B

/B OUTPUT1 connector/ADA-

59

Adjusting point :

1RV203 (L-4)/ADA-59

Specifications :

F = 700

±5 mV

F

Portion D

Portion E

C

Portion A

Portion B