3-26 (E)

HDCU-900 MM

3-6. HD Signal Input/Output Adjustment (HKCU-902)

5.

R mix level adjustment
Measuring point : P

R

/R OUTPUT1 connector/

ADA-59

Adjusting point :

1RV302 (L-4)/ADA-59

Specifications :

Portion G and portion H must be
flat (within 5 mV or less).

6.

R signal level adjustment
Measuring point : P

R

/B OUTPUT1 connector/ADA-

59

Adjusting point :

1RV303 (M-4)/ADA-59

Specifications :

J = 700

±5 mV (terminated at 75 Z)

Setting after Adjustment

. S1 (F-2)/ADA-59 → 0
. BARS button/MSU → OFF

3-6-3. SYNC Output Level Adjustment

Measure : HD waveform monitor

Preparation

. Board extension : ADA-59 board (rear side)
. BARS button/MSU → ON

Adjustment Procedure

Measuring point : Y/G OUTPUT1 connector/ADA-59
Adjusting point :

1RV752 (F-4)/ADA-59

Specifications :

A = 600

±5 mV (terminated at 75 Z)

Setting after Adjustment

BARS button/MSU