6-4. a/d conversion level adjustment, 6-5. clock (74 mhz) duty adjustment – Sony HDCU-900 User Manual

Page 71

Advertising
background image

3-27 (E)

HDCU-900 MM

3-6. HD Signal Input/Output Adjustment (HKCU-902)

3-6-4. A/D Conversion Level Adjustment

Measure : Oscilloscope

Note

Do not connect anything to the VTR connector of the camera.

Preparation

. The Y/P

B

/P

R

output level adjustment (section 3-6-1)

should be completed.

. Board extension : VDA-55 board (HDC-900/950)
. Board extension : ADA-59 board (rear side)
. Connect the Y/G OUTPUT1 connector on the ADA-59

and the RET INPUT1 connector on the ADA-59.

. S1 (F-2)/ADA-59 → C
. BARS button/MSU → ON
. Set on the setup menu of the HDC-900/950 as follows.

TOP MENU : MAINTENANCE
PAGE :

VTR-26P (M9)

ITEM :

VIDEO SEL

→ RET (YPbPr)

. RET1 button/camera → ON

Adjustment Procedure

1.

Measuring point : TP37/extension board (VDA-55)
Adjusting point :

1RV501 (B-3)/ADA-59

Specifications :

A = 0

±5 mV

2.

Measuring point : TP37/extension board (VDA-55)
Adjusting point :

1RV502 (B-4)/ADA-59

Specifications :

B = 1400

±1 0 mV

A

Setting after Adjustment

. S1 (F-2)/ADA-59 → 0
. Return the setting on the setup menu of the HDC-900/

950.

. RET1 button/camera → Return to the original setting.
. BARS button/MSU → OFF

3-6-5. Clock (74 MHz) Duty Adjustment

Measure : Oscilloscope (20 MHz BWLimit: ON)

Note

This adjustment corresponds to the ADA-59 board with
part No. suffix -14.

Preparation

. Board extension : ADA-59 board (rear side)

Adjustment Procedure

Measuring point : TP601 (C-3)/ADA-59
Adjusting point :

1RV1 (E-3)/ADA-59

Specifications :

C = 1.65

±0.04 Vdc

B

A

B

A

=B

C

GND

Advertising
This manual is related to the following products: