Cylinder door strike, Loading door switch – Speed Queen Drying Tumblers SCB50EG User Manual

Page 57

Advertising
background image

55

M412616

CYLINDER DOOR STRIKE

The door strike must be adjusted to have sufficient
tension to hold loading door closed against force of
load tumbling against it. Proper adjustment is when
8 to 15 pounds (35.6 N - 66.7 N) pull is required to
open door.

To adjust, open door, loosen jamnut and turn door
strike screw in or out as required. Retighten jamnut.

LOADING DOOR SWITCH

Loading door switch turns off tumbler any time
loading door is opened. To adjust loading door
switch, follow these steps:

1. Start tumbler following operating instructions

which accompanied it.

2.

Slowly open loading door. Cylinder and heating
system should stop when door is open 3" (7.5
cm) plus or minus 1/4" (0.635 cm).

3.

Slowly close loading door. Loading door switch
should close with an audible “click” when loading
door is closed 3" (7.5 cm) plus or minus 1/4"
(0.635 cm).

4.

If loading door switch does not close when
loading door is closed 3" (7.5 cm) plus or minus
1/4" (0.635 cm):
a. Close loading door completely.
b. Loosen lower screw on switch coupler and

rotate switch coupler COUNTERCLOCKWISE
until it stops.

c. Tighten lower screw on switch coupler.
d. Return to step 1 to verify loading door switch

operation.

Figure 32

T048IE1A

DOOR

STRIKE

DOOR

LATCH

ACORN

NUT

Figure 31

LOADING

DOOR

SWITCH

SWITCH

COUPLER

T275IE1A

Advertising