Sample Sequencer

Operation


To Program:


•

Press the DISPLAY key to select desired function. To select desired POINT number
for the low and high alarms press the NEXT key.


•

Press PROGRAM. The programming arrows light up and the current programmed
value is displayed.


•

Starting at the right digit, pressing the key immediately above the up arrow
(DISPLAY) causes the digit to increment. Press repeatedly until the desired digit is
displayed.


•

Each pressing of the key above the left arrow (NEXT) shifts the active digit one to
the left. The active digit may be incremented using the aforementioned up arrow
key.


•

Each pressing of the key above the right arrow key (ALARM RESET) shifts the active
digit one to the right.


•

Pressing the PROGRAM key again:

ƒ

Turns the arrow lights off.

ƒ

Saves the value in permanent memory.

ƒ

Returns the Sample Sequencer to its normal display.

ƒ

The newly programmed values are active on the next cycle. Press
START/RESET to restart the sequencer using the new values.