SZI 1015-T SZI 1015

XLR-3F/XLR-3M cable

BNC/BNC cable (RG 58, 50

Ω):

GZL 1019 A1, -5, -10

Further SZI 1015 radiators
...

Ǡ Connect a 50 Ω

terminating impedance
to the BNC RF output
socket of the last radiator

.

Alternatively:

connection to

the barrier strip

Power supply cable

Please note:

The last radiator in an RF chain should be provided with a 50

terminating impedance to avoid standing waves in the RF cable.

8

Mounting the Radiators

Installation

Wherever possible, install the radiators such that they are orientated directly towards the infra-red
receivers. The easiest way to achieve this is to mount the radiators as high as possible with a slight
downward inclination. For uniform coverage, the radiators should be installed “decentralised”, for
example in the corners of the room.

Distance between Radiators and Receivers

Please observe a minimum distance of 2 m between radiators and receivers. Smaller distances
could overmodulate the receiver input stage, which would result in a very poor transmission
quality.