53

A P P E N D I X

D

Error Handling

This appendix contains information about how the servers process and log errors.
See the following sections:

■

“Handling of Uncorrectable Errors” on page 53

■

“Handling of Correctable Errors” on page 56

■

“Handling of Parity Errors (PERR)” on page 59

■

“Handling of System Errors (SERR)” on page 61

■

“Handling Mismatching Processors” on page 63

■

“Hardware Error Handling Summary” on page 64

Handling of Uncorrectable Errors

This section lists facts and considerations about how the server handles
uncorrectable errors.

Note –

The BIOS ChipKill feature must be disabled if you are testing for failures of

multiple bits within a DRAM (ChipKill corrects for the failure of a four-bit wide
DRAM).

■

The BIOS logs the error to the SP system event log (SEL) through the board
management controller (BMC).

■

The SP's SEL is updated with the failing DIMM pair's particular bank address.

■

The system reboots.

■

The BIOS logs the error in DMI.