Maintenance 6 troubleshooting, Maintenance – Simer Pumps 2360 User Manual

Page 6

Advertising
background image

Maintenance

6

Troubleshooting

For parts or assistance, call Simer Customer Service at

1-800-468-7867 / 1-800-546-7867

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t

Blown fuse or circuit breaker has tripped

If blown, replace with fuse of proper size or reset circuit breaker

start or run

Low line voltage

If voltage under recommended minimum, check size of wiring from main
switch on property. If OK, contact power company or hydro authority

Defective motor

Replace pump

Pump operates but

Low line voltage

If voltage under recommended minimum, check size of wiring from main

delivers little or no

switch on property. If OK, contact power company or hydro authority.

water

Something caught in impeller

Replace pump

Worn or defective parts

Replace pump

Check valve installed without

Drill a 1/16" - 1/8" (1.6mm - 3.2mm) dia. hole between pump discharge

vent hole

& check valve

Intermittent running

Thermal overload has tripped

Protect the installation from the sun

or pump stopped

Pump cooler water

automatically

Pump has run dry; add water

NOTICE: This pump has no serviceable parts inside the
case. Opening the case will ruin the pump. For obstruc-
tions or blockages of the impeller, replace the pump.

Hazardous voltage; can shock, burn or kill.

Unplug the pump before attempting to clean or work on
the pump.

MAINTENANCE

Risk of electric shock. Can burn or cause

death. Disconnect the power before servicing, repairing,
or working on pump.

The pump’s motor is completely sealed in the motor
housing and does not require any service. Disassembly
of the motor housing or modification or removal of the
power cord voids the warranty. The power cord is non-
replaceable.

Never run the pump dry! Running the pump dry can
damage the seal, causing leakage. This pump is a sub-
mersible type and must be in water at all times for prop-
er operation and cooling.

Periodically clean the pump inlet. This will avoid
impeller rotation being hampered by any debris.