3 displays – Siemens Electrical Lean Switch User Manual
Page 31
![background image](/manuals/152429/31/background.png)
Ports and Displays
Industrial Ethernet
A5E00152007-03
31
4.2.3 Displays
Power Display (green and red LEDs)
The status of the ELS TP40M is indicated by a green and a red LED:
Status
Meaning
lit green
Power supply L+ is connected
not lit
Power supply L+ is not connected or <14 V
lit or flashing red
The red LED should go off after "Power on" after approximately one
minute otherwise the ELS TP40M device is defective.
Port Status Display (green/yellow LEDs)
The status of the ports is signaled by four LEDs:
Status
Meaning
Port 1 to 4 LED lit green
TP link exists, no data reception
Port 1 to 4 LED lit yellow
TP link exists, receiving data at TP port
Port Status Display During Startup
Following startup, the LEDs are lit in the order shown:
● Red LED (approx. 0.5 s)
● Green power LED (green) and all yellow LEDs for approx. 13 s
● Red/green LEDs flash quickly for approx. 1.5 s
The device is operational after a further 3 seconds.