Schumacher Instant Power Jump Starter and DC Power Source IP-95C User Manual
Page 7
•
5
•
If the 12V DC device draws more than 15A or has a short circuit, the internal
4.
circuit breaker of the Instant Power™ will trip and disconnect the power to the
device. Disconnect the 12V DC device. The breaker will automatically reset after
an overload occurs.
The DC power outlet is wired directly to the internal battery. Extended operation of a 12V
DC device may result in excessive battery drain. Recharge immediately after unplugging
the 12V DC device.
Using the USB Port
6.3
The USB port provides up to 500mA at 5V DC.
Ensure the battery clips are securely clipped on the storage holders.
1.
Turn the Instant Power™ On/Off switch to the ON (clockwise)
2.
position.
Plug the device into the USB port
3.
on the front panel.
Turn the USB device on.
4.
Reverse these steps when finished using the USB port.
5.
Charge the Instant Power™ as soon as possible after using the USB port.
6.
Using the Air Compressor
6.4
RISK OF EXPLOSION.
Read the instructions of the product being inflated before using the compressor.
Avoid overinflation, do not exceed the manufacturer’s recommended pressures.
Do not leave the air compressor unattended during use.
Ensure the battery clips are securely on the storage holders.
1.
Remove the air compressor hose from the storage cleats on the back of the
2.
Instant Power™. Install adapters as necessary.
Attach the air compressor hose to the product or accessory to be inflated by flipping
3.
down the lever.
Toggle the Compressor Switch up to the ON position and inflate the product.
4.
When the product is inflated to the proper air pressure (using the air compressor
5.
gauge), toggle the Compressor Switch down to the OFF position and remove the hose.
Do not run for more than 10 minutes maximum at a time. Allow the Instant Power™
6.
to cool down for 10 minutes before using again.
NOTE: To prevent overheating, the compressor has built-in thermal protection that
will turn the compressor off before it overheats. If the compressor shuts off, wait a few
minutes and it will automatically restart when the compressor cools.
NOTE: The air compressor is rated for 150 PSI.
MAINTENANCE INSTRUCTIONS
7.
After use and before performing maintenance, unplug and disconnect the Instant
7.1
Power™ (see sections 3 and 4).
Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery clips,
7.2
cords, and the Instant Power™ case.
Ensure that all of the Instant Power™ components are in place and in good
7.3
working condition.
Servicing does not require opening the unit, as there are no user-serviceable parts.
7.4
All other servicing should be performed by qualified service personnel.
7.5
MOVING AND STORAGE INSTRUCTIONS
8.
Store the Instant Power™ in an upright position.
8.1
Store inside, in a cool, dry place.
8.2
Do not store the clips on the handle, clipped together, on or around metal, or clipped
8.3
to cables. The clips on the Instant Power™ are live and will produce arcing or sparking
if they come in contact with each other. To prevent accidental arcing, always keep the
clips on the storage holders when not using it to jump start a vehicle.
If the Instant Power™ is moved around the shop or transported to another location, take
8.4
care to avoid/prevent damage to the cords, clips and Instant Power™. Failure to do so
could result in personal injury or property damage.