Using the preset white balance settings – Sony 300PF User Manual

Page 101

Advertising
background image

Chapter 5

Adjustments and Settings

101

Chapter 5 Adjustments and Settings

To save the white balance adjustment for different
lighting conditions, repeat steps

2

to

4

above. You can

save two different values for the white balance, in
memories A and B.

To recall a white balance value from memory

Before beginning shooting, set the W. BAL switch to
the A or B position. This automatically sets the
camcorder to the white balance adjustment saved in
the corresponding memory.

If white balance adjustment cannot be
completed automatically

The warning message “AUTO WHITE -NG-” appears
in the viewfinder.
Make the necessary corrections, then carry out the
process again.

Warning messages for white balance adjustment

Using the Preset White Balance
Settings

The camcorder provides two preset white balance
settings, for instant shooting with approximately the
correct adjustment.
There are also particular shooting conditions under
which the preset values may give better results than the
human eye adjustment.

1

Set the W. BAL switch to PRESET.

2

Set the FILTER control.

The white balance is automatically adjusted for
3200 K when the FILTER control is in position 1
and for 5600 K in position 2, 3 or 4.

To switch the 3200 K preset to the 3000 K
preset

Change the setting in advanced menu page 3 (see page
85).
Depending on shooting conditions, select the
better one.

Message

Meaning and corrections to be made

AUTO WHITE

-NG-

:LOW LIGHT

TRY AGAIN

Light level is too low.
• Increase the illumination level, open

the iris, or use the GAIN switch to
increase the video signal level.

• Check the setting of the FILTER

control.

• After these checks, retry the

adjustment.

AUTO WHITE

-NG-

:

??

TRY AGAIN

The subject is not white, or the lighting
level is too high.
• Use a white subject.
• Lower the illumination level, stop down

the iris, or use the GAIN switch to
decrease the video signal level.

• Check the setting of the FILTER

control.

• After these checks, retry the

adjustment.

BARS

AUTO WHITE

-NG-

:C.TEMP.LOW

CHG.FILTER

TRY AGAIN

The color temperature is too low. Try
the following, in this order of
precedence.
(1) If the FILTER control is in position 2,

3 or 4, change it to position 1, then
retry the adjustment.

(2) Check that the subject is completely

white, then retry the adjustment.

(3) The color temperature may be

outside the range of the camcorder.
Fit an appropriate color temperature
conversion filter, then retry the
adjustment.

AUTO WHITE

-NG-

:C.TEMP.HI

CHG.FILTER

TRY AGAIN

The color temperature is too high. Try
the following, in this order of
precedence.
(1) If the FILTER control is in position 1,

change it to position 2, 3 or 4, then
retry the adjustment.

(2) Check that the subject is completely

white, then retry the adjustment.

(3) The color temperature may be

outside the range of the camcorder.
Fit an appropriate color temperature
conversion filter, then retry the
adjustment.

The W. BAL switch is in the PRESET
position.
Move the W. BAL switch to the A or B
position.

WHITE:PRESET

The camcorder is outputting a color bar
signal.
Move the OUTPUT/DL/DCC+ switch to
one of the CAM positions.

Advertising