Maintenance indicators – Sharp XR-10S User Manual

Page 52

Advertising
background image

48

Maintenance Indicators

About the lamp indicator

■ When the remaining lamp life becomes 5% or less, (yellow) and “Change The Lamp” will be

displayed on the screen. When the percentage becomes 0%, it will change to

(red), the lamp will

automatically turn off and then the projector will automatically enter standby mode. At this time, the
lamp indicator will illuminate in red.

If you try to turn on the projector a fourth time without replacing the lamp, the projector will

not turn on.

About the temperature warning indicator

If the temperature inside the projector increases, due to blockage of the air vents, or the setting location,

” will illuminate in the lower left corner of the picture. If the temperature keeps on rising, the lamp

will turn off and the temperature warning indicator will blink, the cooling fan will run, and then the projec-
tor will enter standby mode. After “

” appears, be sure to perform the measures described on page

49

.

Lamp indicator

■ The warning lights (power indicator, lamp indicator and temperature warning indicator) on the

projector indicate problems inside the projector.

■ If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate

red, and the projector will enter standby mode. After the projector has entered standby mode,
follow the procedures given below.

Temperature warning indicator

Power indicator

Lamp indicator

Red on

Power indicator

Indicators on the Projector

Green on

Normal (Standby)

Normal (Power on)

Green on

Green blinks

Normal

The lamp is warming up or shutting down.

Temperature warning
indicator

Off

Red on

Normal

The internal temperature is abnormally
high. (See page

49

.)

Red blinks

Abnormal (See page

49

.)

Red on

The lamp is shut down abnormally or
requires to be changed. (See page

49

.)

Green blinks

Normal (Cooling)

Top View

Advertising
This manual is related to the following products: