4 power control, 1 voltage measurement – Samsung S3F84B8 User Manual

Page 15

Advertising
background image

S3F84B8_ALL-IN-ONE IH COOKER_AN_REV 0.00

2 HARDWARE IMPLEMENTATION

2-9

2.4 POWER CONTROL

Power is the product of voltage and current (P = V x I). Figure 2-5 and

Figure 2-6

show the measurement circuit of

system voltage and current, separately.

2.4.1 VOLTAGE MEASUREMENT

Figure 2-5

shows the circuit diagram for voltage measurement and surge protection.

R20
29K

+

C16
10uF/50V

SY S_V

R27
6K8

C18
221

Surge_P

220 VAC

AC_L

D9

1N4007

AC_N

D10

1N4007

surge protection

R17
470K/0.5W

R19
820K/0.5W

R18
820K/0.5W

C15

102/1KV

Figure 2-5 Voltage Measurement and Surge Protection Circuit

Resistor divider decreases the voltage level to the proper ADC range.

Advertising