2 current measurement, Figure 2-6 current measurement circuit, Figure 2-6 – Samsung S3F84B8 User Manual

Page 16

Advertising
background image

S3F84B8_ALL-IN-ONE IH COOKER_AN_REV 0.00

2 HARDWARE IMPLEMENTATION

2-10

2.4.2 CURRENT MEASUREMENT

R4 1K

OPA_O

R13 36K

RW1

10K

OPA_N

C10
104J

SY S_I

+

C12

1uF/16V

CURRENT

R14 100K

R15
22K

S

3F84B8

Rf

R

1

OPA

_

N

OPA _

P

OPA _O

Gain

=

-

Rf/R1

Figure 2-6 Current Measurement Circuit

In the IH cooker system, the current can go as high as 10A. To avoid excessive energy loss, a constantan is used
to change the current signal to voltage signal, which is then amplified by the integrated OPA. Finally, the amplified
signal enters the ADC module. Note that the signal (OPA_N) reaching OPA is negative as compared to MCU
GND. Therefore, OPA has to work as an inverting amplifier with negative gain.

Either the OPA offset or the resistance deviation can lead to inconsistency of output power among different chips.
To get precise power control, two calibrating methods are used. In hardware, a variable resistor (RW1) is chosen,
whereas in software algorithm, the overall offset is measured and calculated before the system starts working. It
likes the quiescent bias that should be removed during normal operation. This way the output power can be
controlled within 10W deviation.

Advertising