1 configuration guidelines, Configuration guidelines – Sun Microsystems Sun StorEdge A3500FC User Manual

Page 12

Advertising
background image

1-2

Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999

1.1

Configuration Guidelines

Use the following guidelines to install and cable or reconfigure your StorEdge A3500
system.

■

The part number for the 12 meter SCSI host cable is 530-1886-xx.

■

Do not exceed a SCSI bus length of 25 meters (82 feet).

■

Make sure that the last StorEdge A3500 controller module in any daisy chain has
a total of two terminators—one in each SCSI OUT port.

■

If you are adding a controller module to an already existing configuration, halt all
activity on the SCSI bus before removing any SCSI cables.

■

Once you finish cabling the devices and powering on, reboot the system by
typing

boot -r

at the

ok

prompt before beginning any SCSI bus activity.

■

Perform a system check to make sure that SCSI connections are secure. Look for
fault LEDs on the hardware or error messages in the RAID Manager GUI.

Note –

Refer to your server and rack documentation for instructions on grounding

the StorEdge A3500 expansion cabinet.

Advertising