BURNER ADjUSTMENTS

(QUALIFIED TECHNICIANS ONLY)

Flame Appearance and Sooting

Proper flame appearance is a flame which is

blue at the base and becomes yellowish-orange

in the body of the flame. When the appliance

is first lit, the entire flame may be blue and

will gradually turn yellowish-orange during

the first 15 minutes of operation. If after a

short period the flame stays lowered blue, or

if the flame is orange with evidence of sooting

(black tip), the air shutter opening may need

to be adjusted.

If the air shutter openings closed too far,

sooting may develop. Sooting is indicated

by black puffs developing at the tips of very

long orange flames. Sooting results in black

deposits forming on the logs, appliance inside

surfaces and on exterior surfaces adjacent

to the vent termination. Sooting is caused

by incomplete combustion in the flames and

lack of combustion air entering the air shutter

opening. To achieve a warm yellowish-orange

flame with an orange body that does not soot,

the shutter opening must be adjusted between

these two extremes.

Air Shutter Adjustment Guidelines

• If there is smoke or soot present, first check

the log set positioning to ensure that the

flames are not impinging on any of the logs.

If the log set is properly positioned and a

sooting condition still exists, then the air

shutter opening should be increased.

• The more offsets in the vent system, the larger

the air shutter opening will need to be.

• An appliance operated with the air shutter

opened too far, may have flames that appear

blue and transparent. These weak, blue and

transparent flames are termed anemic.

• Propane models may exhibit flames which

candle or appear stringy. If this is present

and persists, adjust the air shutter to a more

closed position, then operate the appliance

for a few more minutes to ensure that the

flame normalizes and the flames do not

appear sooty.

The following chart is provided to aid you in

achieving the correct air shutter adjustment

for your installation.

Air Shutter Adjustment Guidelines

:

Amount of

Primary Air

Flame

Color

Air Shutter

Adjustment

If air shutter is

closed too far

Flame will

be orange

Air shutter

gap should be

increased

If air shutter is

open too far

Flame will

be blue

Air shutter

gap should be

decreased

Figure 16

WARNING

Air shutter adjustment should

only be performed by a qualified

professional service technician.

WARNING

Ensure front glass panel is in place

and sealed during adjustment.

CAUTION

The air shutter door and nearby

appliance surfaces are hot. Exer-

cise caution to avoid injury while

adjusting flame appearance.

CAUTION

Carbon will be produced if the air

shutter is closed too much. Any

damage due to carboning result-

ing from improperly setting the

air shutter is not covered under

the warranty.

Burner Air Shutter Adjustment Procedure

1. Locate adjustment rod and adjust air shutter

to the standard setting as shown in Figure

16 (adjustment rod is located in the lower

control compartment). Note: Rotating the

adjustment rod counterclockwise increases

air and clockwise decreases air.

. Light appliance (follow lighting procedure on

lighting label in control compartment or see

homeowners manual).

. Allow the burner to operate for at least 15 min-

utes while observing the flame continuously

to ensure that the proper flame appearance

has been achieved (see Figure 15). If the

following conditions are present, adjust

accordingly.

• If flame appears weak or sooty, adjust

the air shutter, incrementally, to a more

open position until the proper flame

appearance is achieved.

• If flame stays lowered blue, adjust the

air shutter, incrementally, to a more

closed position until the proper flame

appearance is achieved.

4. Leave the control knob (off/pilot/on) in the

ON position and the burner OFF/ON switch

OFF (& remote switches, if applicable).

5. When satisfied that the burner flame appear-

ance is normal, close the lower control

compartment door.

Burner Air Shutter Adjustment

Adjustment Rod Up

(Fully Open Position)

Air Shutter

Adjustment Rod Down

(minimum air opening

position)

Burner Tube

Adjustment Setscrew

Millivolt Appliance Checkout
The pilot flame should be steady, not lifting

or floating. Flame should be blue in color with

traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator

(thermopile) and the top 1/8" minimum (tip)

of the quick drop out thermocouple should be

engulfed in the pilot flame. The flame should

project 1" (25 mm) beyond the hood at all three

ports. See

Figure

s

17 or 18.

To light the burner, refer to the lighting instruc-

tions on Pages 16 & 17.

Main Burner Factory Air Shutter

Opening Setting - Inches (millimeter)

Model

Natural

Gas

Propane

Gas

SSBV-50

1/16"

(1.58 mm)

1/4"

(6.5 mm)

SSBV-405

1/16"

(1.58 mm)

1/4"

(6.5 mm)

Advertising