Clean Lower Control Compartment

Keep lower control compartment clean by

vacuuming or brushing it out at least twice a

year (also clean the air venturi with a brush or

wire). More frequent cleaning may be required

due to accumulation of lint from carpeting,

bedding materials, pet hair, spider webs, etc.

It

is very important that control compartments,

burners, circulating air passageways and air

venturi on the appliance are NOT obstructed

in any way.
Cleaning Glass

(see Front Glass Enclosure Panel, Removal and

Installation on Pages 7 & 8) Note: Clean glass

after first two weeks of operation (after Burn-In

period is over) and then only when necessary

and when the fireplace is cool. Wipe surface

with clean, dampened, soft cloth. Follow with

dry, soft towel as desired. Take care not to

scratch the glass surface.
The viewing glass should be cleaned periodi-

cally to remove any build-up caused from the

following (on next page):

Before re-lighting the fireplace, refer to the

lighting instructions in this manual. Instruc-

tions are also found on pull-out panels

located below the glass door in the control

compartment.

WARNING

Turn off gas and electrical power

before servicing the appliance.

CAUTION

Wear gloves and safety Glasses

for protection while doing

required maintenance

.

IMPORTANT

Always verify proper operation

after servicing.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

5

Figure 3

Honeywell Electronic Gas Valve

FF

O

NI

P

S

I

N

O

L

O

RT

N

O

C

GI

N

TIER

Manifold Pressure

Port

ON / OFF Switch

Inlet

Pressure

Port

Electronic Gas

Control Valve

Electronic Appliances -To light electronic appli-

ances refer to the detailed lighting instructions

found on Pages 18 & 19 of these instructions.

Electronic appliance lighting instructions may

also be found on the pull out lighting instruction

labels attached to the gas control valve.

If your electronic appliance is equipped with an

optional remote wall switch or remote control kit

the appliance main burner may be turned on and

off with the wall switch or remote control.

If your electronic appliance is not equipped

with a wall switch or remote control, the main

burner must be turned off and on with the gas

control switch. Toggle the switch from ON to

OFF to operate the main burner .

Variable Flame Height Adjustment

(Millivolt Appliances only)

1. All Millivolt appliances are equipped with a

variable gas control valve. Flame height for

these models may be adjusted through a

range between fixed low and high settings

while the appliance is in operation. Adjust

the flame height as desired after lighting the

appliance by rotating the variable adjustment

control knob (HI/LO) located on the front of

the valve (refer to Figures 4 & 5).

. During the first initial burns of these appli-

ances, there will be some odor emitted (see

Burn-In Period on Page 4).

. Keep the lower control compartment clean

by vacuuming or brushing at least twice a

year. More frequent cleaning may be required

due to excessive lint from carpeting, bedding

materials, pet hair, etc.

It is very important

that the control compartments, burners

and circulating air passageways of the

appliance are kept clean.

4. Always turn off gas to the pilot (millivolt

appliances) and let the appliance cool down

before cleaning. Before re-lighting, refer

to the lighting instructions in this manual.

Lighting instructions may also be found

on the pull out lighting instruction labels

attached to the gas control valve.

5. Always keep the appliance area clear and

free from combustible materials, gasoline

and other flammable liquids.

6. Remember, Millivolt appliances have a continu-

ous burning pilot flame. Exercise caution when

using products with combustible vapors.

Honeywell Millivolt Gas Valve

Figure 5

ON

OFF

P

IL

OT

LO

HI

OF

F

ON

OF

F

ON

Optional Blower OFF/ON

Rocker Switch

SIT Millivolt Gas Valve

Gas

Outlet

Gas

Inlet

Pilot Adjustment

Screw

Terminals

TPTH,TP & TH

Figure 4

HI

L O W

HT

PT

HT

PT

PILO

T

PIL

OT

ON

ti

OFF

IN

OUT

O

FF

O

N

O

FF

O

N

HI/LO Variable

Flame Height

Adjustment

Manifold Pressure Tap

Inlet Pressure Tap

Piezo Igniter

Main Gas

Control Knob

OFF/PILOT/ON

Piezo Igniter

Optional Burner OFF/ON

Rocker Switch

Piezo Igniter

Optional Blower OFF/ON

Rocker Switch

Optional Burner OFF/ON

Rocker Switch

HI/LO Variable

Flame Height

Adjustment

Main Gas

Control Knob

OFF/PILOT/ON

Manifold Pressure

Tap

Piezo Igniter

Inlet Pressure Tap

Gas

Outlet

Gas

Inlet

MAINTENANCE
(See Maintenance Schedule, Page 20)

Refer to the maintenance schedule for maintenance

tasks, procedures, periodicity and by whom they

should be performed. Always verify proper opera-

tion of the appliance after servicing.