4. control codes used for peripheral units, 5. auto cutter control (sp240 type only), 6. other control codes – Star Micronics SP200F User Manual
Page 23

– 20 –
ENGLISH
6-4. Control Codes Used for Peripheral Units
Control codes
Hexadecimal codes
Function
<ESC> <BEL> n1 n2
1B 07 n1 n2
Adjust drive pulse width for peripheral unit (Default
setting)
<BEL>
07
Deferred drive command “A” for peripheral unit 1
<FS>
1C
Immediate drive command “B” for peripheral unit 1
6-5. Auto Cutter Control (SP240 type only)
Control codes
Hexadecimal codes
Function
<ESC> “d” “0”
1B 64 30
Full-cut command to the auto cutter
<ESC> “d” <0>
1B 64 00
<ESC> “d” “1”
1B 64 31
Partial-cut command to the auto cutter
<ESC> “d” <1>
1B 64 01
6-6. Other Control Codes
Control codes
Hexadecimal codes
Function
<CAN>
18
Cancel print data in buffer
<ESC> “@”
1B 40
Initialize printer
<ESC> “e” “0”
1B 65 30
ON LINE/FEED switch valid
<ESC> “e” <0>
1B 65 00
(Default setting)
<ESC> “e” “1”
1B 65 31
ON LINE/FEED switch invalid
<ESC> “e” <1>
1B 65 01
<ESC> “f” “0”
1B 66 30
ON LINE switch valid
<ESC> “f” <0>
1B 66 00
(Default setting)
<ESC> “f” “1”
1B 66 31
ON LINE switch invalid
<ESC> “f” <1>
1B 66 01