6-4. Control Codes Used for Peripheral Units

Control codes

Hexadecimal codes

Function

<ESC> <BEL> n1 n2

1B 07 n1 n2

Adjust drive pulse width for peripheral unit (Default
setting)

<BEL>

07

Deferred drive command “A” for peripheral unit 1

<FS>

1C

Immediate drive command “B” for peripheral unit 1

6-5. Auto Cutter Control (SP240 type only)

Control codes

Hexadecimal codes

Function

<ESC> “d” “0”

1B 64 30

Full-cut command to the auto cutter

<ESC> “d” <0>

1B 64 00

<ESC> “d” “1”

1B 64 31

Partial-cut command to the auto cutter

<ESC> “d” <1>

1B 64 01

6-6. Other Control Codes

Control codes

Hexadecimal codes

Function

<CAN>

18

Cancel print data in buffer

<ESC> “@”

1B 40

Initialize printer

<ESC> “e” “0”

1B 65 30

ON LINE/FEED switch valid

<ESC> “e” <0>

1B 65 00

(Default setting)

<ESC> “e” “1”

1B 65 31

ON LINE/FEED switch invalid

<ESC> “e” <1>

1B 65 01

<ESC> “f” “0”

1B 66 30

ON LINE switch valid

<ESC> “f” <0>

1B 66 00

(Default setting)

<ESC> “f” “1”

1B 66 31

ON LINE switch invalid

<ESC> “f” <1>

1B 66 01