Samsung SMART DOME SCC-C6407 User Manual

Page 9

Advertising
background image

2-1

E

1-11

Setting RS-422A/RS-485 termination

As it is shown in the structure map, when Controller and RS-422A/RS-
485 is connected it should be terminated according to the Cable feature
of impedance on the each end of the transmitting line to transfer the
signals in long distance by controlling the reflection of the signals to the
lowest.

<RS-485 Half Duplex Organization>

n < 32

Termination

SW1-ON

Division

Termination: using numbers 1 and 2 PIN, turn to ON and it will be terminated.

<RS-422A/RS-485 Full Duplex Organization>

Division

Division
SW1-ON
SW2-ON

n < 32

In this chapter, we will check the contents of the package before
installing the SCC-C6407, and prepare a power adapter suitable for
the power supply system.
(Power Consumption: 22W; Voltage: AC24V, 1.5A)
Then, we will install the SCC-C6407 and connect the cables.

Chapter 2 SCC-C6407 Installation

❈ A communication error may occur if you connect multiple cameras

that are assigned the same address in the network.

00600A-SCC-C6407-ENG

8/17/06

3:27

PM

˘`