Sony CPD-E220 User Manual

Page 10

Advertising
background image

CPD-E220/E215E/E220E

VR501

SECTION 3

SAFETY RELATED ADJUSTMENT

3-1

When replacing parts shown in the table below, the

following operational checks must be performed as a

safety precaution against X-ray emissions from the unit.

Allow the unit to warm up for one minute prior to checking

the following conditions:

a) HV Regulator Check

1)

Input white cross hatch signal. (fH = 69 kHz)

2)

CONT maximum and BRT center

3)

Cut off Screen VR (G2).

4)

Input voltage: 120

±

2 VAC

5)

Confirm that the voltage is within the voltage range

shown below.

Standard voltage: 26.9 KV

±

0.4 KV

6)

When replacing components identified by

], make sure

to recheck the High Voltage.

7)

Verify the High Voltage as shown above (26.9 KV

±

0.4

KV) is within specification. If not, set H. SIZE data at

minimum (-127) and then adjust VR501 on "D" Board.

8)

After adjusting the High Voltage within specification,

put the VR cover on VR501 as shown below and apply

sufficient amount of RTV around VR501.

b) HV Protector Circuit Check

1)

Confirm that the voltage between cathode of D517 an

GND is more than 27.5 VDC.

2)

Using an external DC Power supply, apply the voltage

shown below between cathode of D517 on "D" and

GND, and confirm that the HV Hold-Down circuit

works. (Raster disappears) Apply DC Voltage: Less than

35.8 VDC.

Check Condition

• Input voltage

: 120

±

2 VAC

• Input signal

: (fH = 69 kHz), White Cross Hatch

• Controls

: CONT (max) & BRT (center)

• B+ Voltage

: 179

±

3.0 VDC

c) Beam Protector Check (Software logic)

1)

Using an external current source, apply < 1.55mA

between pin qa of FBT (T501) and GND, and confirm

that the raster fades out.

Check Condition

• Input voltage

: 120

±

2 VAC

• Input signal

: (fH = 69 kHz), White Cross Hatch

• Controls

: CONT (max) & BRT (center)

d) B+ Voltage Check

1)

Input white cross hatch (fH = 69 kHz) signal.

2)

CONT (max) & BRT (center)

3)

Input voltage: 120

±

2 VAC

Note: Use NF power supply or make sure that distortion

factor is 3% or less.

4)

Confirm that the voltage is within the voltage range

shown below.

Standard voltage: 179

±

3.0 VDC

HV Regulator
Circuit

HV HOLD
DOWN Circuit

Beam Current
Protector Circuit

Part Replaced (

] )

D board

IC502, T501 (FBT)

D board

D538, R521, T501 (FBT)

D board

IC901, R949, T501 (FBT)

Advertising