Asme – State Industries ASME SSE-5 User Manual

Page 7

Advertising
background image

7

locatInG the new water heater

approVals

Model and ratInG

facts to consIder aBout the locatIon

Carefully choose a location for the new water heater. The placement

is a very important consideration for the safety of the occupants in

the building and for the most economical use of the appliance.

Whether replacing an old water heater or putting the water heater in

a new location, the following critical points must be observed. The

water heater must be located:

1. On a level surface. Shim the channel type skid base as

necessary if levelling is required.

2. Near a floor drain. The heater should be located in an area where

leakage of the tank or connections will not result in damage to the

area adjacent to the heater or to lower floors of the structure.

3. The discharge opening of the temperature and pressure relief

valve should always be piped to an open drain or external to

the building.

4. Close to the point of major hot water usage and the power

supply.

Hot water piping and branch circuit wiring should be as short as possible.

Insulate hot and cold water piping where heat loss and condensation

may be a problem.

Heater construction permits installation, maintenance, and service

work to be performed through the front control panel.

Suggested clearances from adjacent surfaces are 12 inches on top,

30 inches in front for access to the unit.

The heater may be installed on or against combustible surfaces. The

left side and back may be placed flush against adjacent surfaces.

The temperature of the space in which the water heater is installed

must not go below 32°F or above 122°F.

asMe

All models are listed

by Underwriters

Laboratories Inc.

All models meet National

Sanitation Foundation

NSF-5 requirements.