Sun Fire X4100 and Sun Fire X4200 Servers Service Manual • June 2006
Note –
In the following figures, the server is shown from a rear view with the front
cover off and all fans removed to provide visibility.
FIGURE 3-27
Unfastening the Fan Connector Board Securing Screw
b. Slide each fan connector board toward the center of the chassis, to disconnect
them from the front I/O board and to release each board from the locating tabs
on the chassis. See
c. Lift the fan connector boards straight up to remove them from the system.