Siemens M1 User Manual

Page 26

Advertising
background image

25

GSM M1 Module, English: A24859-N4000-A100-1-7677

gsm-m1-e.fm

Technical reference section

6.3.96

This command allows you to load the factory profile that was supplied with the GSM
module.

The AT&V0 command allows you to display the active configuration profile on the screen.

Enter:

AT&V

The GSM module then transfers the information to the computer, which displays it on
the screen.

Example:

You have a GSM module and have loaded the factory configuration by means of the
AT&F command. Now enter the AT&V command. The following is displayed on the
screen:

AT&V

ACTIVE PROFILE:

B99 E1 L2 M1 Q0 V1 X4 Y0 %D0 &C1 &D2 &G0 &Y0

S00:000 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:060 S08:002

S09:006 S10:007 S12:050 S14:6AH S16:00H S18:000 S21:30H S22:46H S23:1CH

S25:005 S26:001 S27:00H

0

STORED PROFILE 0:

B99 E1 L2 M1 Q0 V1 X4 Y0 &C1 &D2 &G0

S00:000 S14:6AH S18:000 S21:30H S22:46H S23:1CH S25:005 S26:001 S27:00H

x

S27:00H

STORED PROFILE 1:

B99 E1 L2 M1 Q0 V1 X4 Y0 &C1 &D2 &G0

S00:000 S14:6AH S18:000 S21:30H S22:46H S23:1CH S25:005 S26:001 S27:00H

x

S27:00H

TELEPHONE NUMBERS:

&Z0=

&Z1=

&Z2=

&Z3=

OK

AT&F - Load factory profile

AT&F

Option

Result

AT&F

If your GSM module stops functioning due to a faulty configuration,
this command resets the module to the factory configuration.

AT&V - Display configuration

Advertising