Sharp ER-A440 User Manual

Page 29

Advertising
background image

If a compare error is found in the check sequence from PASS1 to
PASS6, error print (error code E1) is performed. If there is no error
found to the end of the last address, the operation is completed
normally.
Then the following address check is performed. " " shows a valid
address, and "

" shows an invalid address.

In case of an error, error code E2 is printed.

Check Address

JOB#201(ER-03RA)

200000H

200001H

200002H

200004H

200008H

200010H

200020H

200040H

200080H

200100H

200200H

200400H

200800H

201000H

202000H

204000H

208000H

210000H

220000H

240000H

260000H

3) Check the following items.

Check the termination print.

4) Test termination

The test terminates after printing the termination printout.
Termination print

E01---

200

(data check error)

E02---

200

(address check error)

200

(normal end)

: Error address

[15] RS-232 loop back test

Connect the loop back connector(UKOG-6705RCZZ) to RS232 con-
nector.

1) Key operation

2) Functional description

Control signal check

OUT PUT

INPUT

/ER

/RS

/DR

/CI

/CD

/CS

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

ON

ON

OFF

ON

ON

OFF

OFF

ON

ON

ON

ON

ON

ON

Data communication check
Perform 256-byte branch loop back test between SD and RD.

DATA: $00 - $FF

BAUD RATE: 9600 BPS

Display:

4) Test termination

This check is terminated automatically.
The test terminates with the test and message printed

XX: Error code

E1

ER-DR error

E2

ER-CI error

E3

RS-CD error

E4

RS-CS error

E5

SD-RD error (DATA error)

E6

SD-RD error (DATA error/Flaming error)

2

0

7-SEGMENT DISPLAY:

0

500

CA/AT

5 0 0

Normal end

Error

NG

RS TEST

ER XX

RS TEST

OK

5 – 6

Advertising