BEFORE RETURNING FOR REPAIRS

17.

When a charging problem arises, make certain that the battery is capable

17.1

of accepting a normal charge. Use a good battery to double check all

connections, the AC outlet for a full 120-volts, the charger clips for correct

polarity and the quality of the connections from the cables to the clips and

from the clips to the battery system. The clips must be clean.
When a battery is very cold, partially charged or sulfated, it will not draw

17.2

the full rated amperes from the charger. It is both dangerous and damaging

to a battery to force higher amperage into it than it can effectively use in

recharging.
When an UNKNOWN OPERATING PROBLEM arises, please read the

17.3

complete manual and call the customer service number for information that

will usually eliminate the need for return.

If the above solutions do not eliminate the problem or for

information about troubleshooting or replacement parts,

call toll-free from anywhere in the U.S.A.

1-800-621-5485

7:00 am to 5:00 pm Central Time Monday thru Friday

SPECIFICATIONS

18.

Input Voltage------------------------------------------------------------------------------120 VAC
Output Current Rating---------------------------------------------------------------12V – 1.5A

6V – 1.5A

Maximum Charge Voltage--------------------------------------------------------12V – 14.8V

6V – 7.4V

Maintain Voltage---------------------------------------------------------------------12V – 13.3V

6V – 6.6V

Size----------------------------3⅛” (79.3 mm) H x 7” (177.8 mm) W x 4” (101.6 mm) D
Weight-----------------------------------------------------------------------------2½ lbs (1.08 kg)

REPLACEMENT PARTS

19.

Battery Clip Cable Assembly---------------------------------------------------38-99-001235
Ring Terminal Cable Assembly------------------------------------------------22-99-001950