Making connections, Hub or switch rpu, Rpu 4 – SMC Networks Redundant Power Unit SMCRPU600W User Manual
Page 16

I
NSTALLING
THE
RPU
4
Making Connections
Caution:
Caution:DO NOT connect the RPU to an AC power source
until the DC power cord has been connected to the other
device (hub or switch).
1. Connect one end of the AC cord to the AC receptacle on the
supported devices (hubs or switches), and the other end to a grounded
power outlet.
2. Use the provided star-head screwdriver to loosen the screws on the
D-sub receptacle faceplates and remove the faceplates from both the
RPU and the supported device (hub or switch).
3. Connect one end of the DC cord to the redundant power receptacle
on the other device (hub or switch), and the other end to the IEC
receptacle on the RPU.
4. Connect one end of the AC cord to the AC receptacle on the RPU,
and the other end to a grounded power outlet. The Power LED on the
RPU should light up.
SNMP/RMON Module
RS232
EM3570-Agent
DC OUTPUT
DC OUTPUT
3.3V
5V
12V
9A
5A
0.6A
100-240V~ 50-60Hz 2A
Hub or Switch
RPU
Circuit A
Circuit B
(1)
(1)
(3)
(3)
(4)
(4)