English, Volt 2 1, Battery – KTM 640 LC4 ENDURO User Manual

Page 33: Charging the battery

Advertising
background image

ENGLISH

32

Battery

The battery is located under the seat and is maintenance-free.
It is not necessary to check the electrolyte level or to refill water. Simply
keep the battery poles clean and slightly grease them with an acid-free
grease if necessary.

REMOVING THE BATTERY:
Remove screws

1

and swing retaining bracket and voltage regulator out of

the way.
First disconnect the negative and then the positive pole of the battery.
Remove battery.
When replacing, connect first the positive and then the negative pole.

ƽ

WARNING

ƽ

– I

F ELECTROLYTE

(

SULPHURIC ACID

)

LEAKS FROM THE BATTERY

,

PROCEED WITH GREAT

CARE

. T

HE ELECTROLYTE CAN CAUSE SEVERE BURNS

.

– I

N THE CASE OF SKIN CONTACT RINSE THOROUGHLY WITH WATER

.

– I

N THE CASE OF CONTACT WITH THE EYES

,

THOROUGHLY RINSE EYES WITH WATER

FOR AT LEAST

15

MINUTES

. I

MMEDIATELY CONSULT A DOCTOR

.

– T

HE BATTERY IS A CLOSED MODEL BUT CAN NEVERTHELESS EMIT EXPLOSIVE GASES

.

A

VOID SPARKS AND OPEN FIRE NEAR THE BATTERY

.

– D

EFECTIVE BATTERIES MUST BE STORED OUT OF THE REACH OF CHILDREN

. E

NSURE

PROPER DISPOSAL OF DISCARDED BATTERIES

.

!

CAUTION

!

– T

O AVOID DAMAGE

,

DO NOT REMOVE THE LOCKING BAR

2

!

– N

EVER DISCONNECT THE BATTERY WHILE THE ENGINE IS RUNNING

. T

HIS WILL

DESTROY THE RECTIFIER

-

REGULATOR

.

– T

HE BATTERY MUST BE INSTALLED WITH THE TERMINALS FACING THE FRONT

(

AS

SHOWN IN THE ILLUSTRATION

),

OTHERWISE ELECTROLYTE CAN ESCAPE

.

BATTERY STORAGE:
When preparing the motorcycle for a longer period of standstill, remove the
battery and recharge it. Storage temperature: 0 - 35°C (30 - 95°F). Do not
expose to direct sunlight.

Charging the battery

NOTE: A battery charger, item no. 58429074000 is available from your
KTM dealer.
You can also use the battery charger to test the battery's off load voltage,
startability and the generator capacity.

Remove the battery and check the charging level. Use a voltmeter to
measure the voltage between the battery poles (off-load voltage).
Accurate results can only be obtained if the battery has neither been charged
nor discharged during a period of 30 minutes preceding the measuring.
Recharging is not required if the voltage exceeds 12.4 V.
Recharge if the voltage is below 12.4 V.

CHARGING:
Charge the battery for 5 to a max. of 10 hours with 0.9 amperes and a
max. of 14.4 volts.
For a quick charge, do not charge the battery longer than 1 hour with 4.5
amperes and a max. of 14.4 volts.

!

CAUTION

!

– I

F THE CHARGE CONDITION CANNOT BE ESTABLISHED

,

THE BATTERY MAY ONLY BE

CHARGED

5

TO A MAX

.

OF

10

HOURS WITH

0.9

AMPERES AND A MAX

.

OF

14.4

VOLTS

.

– A

LWAYS CONNECT THE BATTERY TO THE CHARGING UNIT BEFORE TURNING THE

CHARGING UNIT ON

.

– W

HEN

RECHARGING

THE

BATTERY

IN

CLOSED

ROOMS

THERE

IS

SUFFICIENT

VENTILATION

. E

XPLOSIVE GASES ARE RELEASED DURING THE BATTERY CHARGING

PROCESS

.

– C

HARGING TIME AND CHARGING VOLTAGE SHOULD NOT EXCEED THE STATED VALUES

.

O

THERWISE ELECTROLYTE WILL BE RELEASED THROUGH THE SAFETY VALVES

.

– A

VOID QUICK CHARGING IF POSSIBLE

.

– T

O AVOID DAMAGE

,

DO NOT REMOVE THE LOCKING BAR

.

VOLT

2

1

Advertising