D. specifications, Connected loads – Karcher HD 6000 C User Manual

Page 16

Advertising
background image

HD 4000 C / HD 6000 C

English

5.956-648 A10369 (06/98)

2. Connected Loads

D. Specifications

D4

HD 6000 C

1.967-045

HD 6000 C

1.967-045

with hot-water

accessory kit

2.638-697

Mains power:

Power type

3 ~ 50 Hz

3 ~ 50 Hz

Voltage

V

400

400

Nominal load (max.)
with water temp. of 20°C

kW

15

15

Power supply cable

mm²

4 x 10

4 x 10

Control cable

mm²

5 x 1.5

5 x 1.5

Motor starter (type)

External pre-fusing

A
slow

50

50

Water:

Flow volume

L/h

5600

5600

Max. supply temperature

°C

60

80

Min. flow pressure

bar

2

2

Max. flow pressure

bar

6

6

Supply line, nominal dia.

mm

40

40

Cooling water:

Flow volume

L/h

250

250

Supply temperature

°C

approx. 10 to 18

approx. 10 to 18

Min. flow pressure

bar

2

2

Max. flow pressure

bar

8

8

Supply line, nominal dia.

mm

15

15

Advertising