F. Trouble Shooting

F2

Problem

Possible cause

Remedy

by whom

General fault and
“Water supply fault”
LED light up on
printed circuit board

Insufficient water in
float tank

Check site water supply

Operator

Temperature of the water
inlet too high

Reduce inlet temperature

Operator

General fault and
“HD pump
temperature fault”
LED light up on
printed circuit board

Cooling water quantity too
low:

Strainer in pressure reduction
valve contaminated

Clean strainer

Operator

Mains water pressure too low Raise pressure

Operator

Cooling coil calcified,
solenoid valve defective

Decalcify,
replace solenoid valve

Operator

Oil level too low

Check oil level

Customer
Service

Oil change not made, owing
to which there is oil carbon
under the piston guide shoes,
piston seizing.

Check pump parts,
replace as necessary.
Make an oil change

Customer
Service

General fault and
“Admission pressure
of hot-water pump
too low” LED light
up. (Only with ABS
hot water)

Rotation direction of
precompression pump wrong

Change rotation direction

Electrician

Pressure switch
precompression hot-water
pump in the ABS hot water
defective

Replace pressure switch

Customer
Service

General fault and
“Drop in system
pressure” LED light
up on the printed
circuit board (flow
without pressure
longer than
15 seconds)

Too many utilisers
simultaneously opened

Close down some utilisers Operator

Pipe burst in the
high-pressure network

Turn off installation and
repair pipeline

Customer
Service

Pressure switch defective

Replace pressure switch

Customer
Service