Processing, Chemicals, Replenishment rates – Kodak 2403 User Manual

Page 3: Processing sequence, Sensitometric data

Advertising
background image

KODAK TRI-X AEROGRAPHIC Film 2403 KODAK TRI-X AERECON Film SO-050

AS-24

3

PROCESSING

KODAK TRI-X AEROGRAPHIC and AERECON Films
can be processed in the KODAK VERSAMAT Film
Processor, Model 11 or 1140, with KODAK VERSAMAT
885 Chemicals, KODAK VERSAMAT 641 Chemicals, or
KODAK VERSAMAT Chemicals, Type A.

Mechanized processing in roller-transport processors

offers the advantages of uniform treatment of all portions of
the roll, freedom from banding, and absence of significant
density variations from ends of the roll to the center. Refer to
the operator’s manual for the processor set-up information,
but in all cases, the fixer replenisher should be introduced
into tank No. 5 of the processor with a countercurrent flow
to tank No. 3, where it overflows to a collection or recovery
system.

General instructions for setting the machine dryer

temperature are included in these pages. However, the
temperature of the dryer may require some further
adjustment, depending upon the ambient temperature
conditions in the processing area. Usually it is best to set the
temperature approximately 3

°

F (2

°

C) above that required to

dry unexposed, processed film.

Chemicals

The following KODAK VERSAMAT Chemicals may be
used in both the Model 11 and Model 1140 VERSAMAT
Processors.

KODAK VERSAMAT 885 Developer Starter

KODAK VERSAMAT 885 Developer Replenisher

KODAK VERSAMAT 885 Fixer and Replenisher

KODAK VERSAMAT 641 Developer Starter

KODAK VERSAMAT 641 Developer Replenisher

KODAK VERSAMAT 641 Fixer and Replenisher

KODAK VERSAMAT Developer Starter, Type A

KODAK VERSAMAT Developer Replenisher, Type A

KODAK VERSAMAT Fixer and Replenisher, Type A

Notice: Observe precautionary information on product labels and
Material Safety Data Sheets.

Replenishment Rates

Basic developer and fixer replenishment rates, in millilitres
per square inch of film processed, vary depending upon the
type of chemicals used. The following rates apply to
processing in the VERSAMAT Processor, Models 11 and
1140.

Processing Sequence

*

For KODAK VERSAMAT Chemicals, Type A, use 90

°

F (32

°

C).

Sensitometric Data

Fixing: Adequate fixing is obtained at machine speeds
up to and including 20 feet per minute.

Washing: With two developer racks, LE-100 keeping
quality is obtained at process machine speeds up to 10
feet per minute, and LE-10 is obtained up to and including
20 feet per minute. (LE = Life Expectancy)

Drying: Adequate drying is obtained at machine speeds
up to and including 15 feet per minute.

Basic Replenishment Rates (mL/in

2

)

KODAK VERSAMAT Chemicals

885

641

Type A

Developer

0.36

0.34

0.20

Fixer

0.45

0.68

0.34

KODAK VERSAMAT Processor, Model 11

(all recommended chemicals)

Processing

Step

No. of

Racks

Path

Length

Temperature

Develop

*

1 or 2

1.2 or 2.4 m

(4 or 8 ft)

85

±

0.5

°

F

(29.5

±

0.3

°

C)

Fix

3

3.6 m

(12 ft)

85

°

F (29.5

°

C),

nominal

Wash

2

2.4 m

(8 ft)

2 to 6

°

F (1 to 3

°

C) below

developer temperature

Dry

2.4 m

(8 ft)

135 to 145

°

F (57 to 63

°

C)

KODAK VERSAMAT 885 Chemicals, Model 11

Machine

Speed

(fpm)

1 Developer Rack

2 Developer Racks

Average

Gamma

ISO A D-min

Average

Gamma

ISO A D-min

85

°

F (29.5

°

C)

5

1.10

640

0.21

1.80

800

0.28

10

0.70

400

0.14

1.40

640

0.15

15

0.55

250

0.13

1.10

640

0.12

20

0.41

125

0.13

0.95

500

0.12

25

0.36

100

0.12

0.80

400

0.12

Advertising
This manual is related to the following products: