Processing sequence sensitometric data – Kodak 2403 User Manual

Page 4

Advertising
background image

4

KODAK TRI-X AEROGRAPHIC Film 2403 KODAK TRI-X AERECON Film SO-050

AS-24

Fixing: Adequate fixing is obtained at machine speeds
up to and including 10 feet per minute.

Washing: LE-100 keeping quality is obtained at process
machine speeds up to and including 5 feet per minute.
(LE = Life Expectancy)

Drying: Adequate drying is obtained at machine speeds
up to and including 20 feet per minute.

Fixing: Adequate fixing is obtained at machine speeds
up to and including 10 feet per minute.

Washing: LE-10 keeping quality is obtained at machine
speeds up to and including 8 feet per minute. (LE = Life
Expectancy)

Drying: Adequate drying is obtained at machine speeds
up to and including 12 feet per minute.

KODAK VERSAMAT 641 Chemicals, Model 11

Machine

Speed

(fpm)

1 Developer Rack

2 Developer Racks

Average

Gamma

ISO A D-min

Average

Gamma

ISO A D-min

85

°

F (29.5

°

C)

5

0.80

400

0.15

1.15

640

0.17

10

0.55

160

0.14

0.85

400

0.15

15

0.65

250

0.34

KODAK VERSAMAT Chemicals, Type A, Model 11

Machine

Speed

(fpm)

1 Developer Rack

2 Developer Racks

Average

Gamma

ISO A D-min

Average

Gamma

ISO A D-min

90

°

F (32

°

C)

5

2.05

1000

0.16

10

1.10

500

0.13

1.35

800

0.15

15

0.95

320

0.13

1.00

500

0.14

20

0.85

250

0.14

0.90

400

0.14

Processing Sequence

Sensitometric Data

KODAK VERSAMAT Chemicals. Type A; Model
1140

This is not a primary processing recommendation, although
satisfactory results can be obtained at processor speeds up to
10 feet per minute. Refer to the processing conditions and
sensitometric data for the KODAK VERSAMAT Processor,
Model 11, above.

KODAK VERSAMAT Processor, Model 1140

(all recommended chemicals)

Processing

Step

No. of

Racks

Path

Length

Temperature

Develop

1 or 2

1.2 or 2.4 m

(4 or 8 ft)

99 or 104

±

0.5

°

F

(37 or 40

±

0.3

°

C)

Fix

3

3.6 m

(12 ft)

99 or 104

°

F

(37 or 40

°

C), nominal

Wash

2

2.4 m

(8 ft)

2 to 6

°

F (1 to 3

°

C) below

developer temperature

Dry

2.4 m

(8 ft)

Up to 149

°

F (65

°

C)

KODAK VERSAMAT 885 Chemicals, Model 1140

Machine

Speed

(fpm)

1 Developer Rack

2 Developer Racks

Average

Gamma

ISO A D-min

Average

Gamma

ISO A D-min

99

°

F (37

°

C)

10

0.90

640

0.21

20

0.65

320

0.16

1.00

640

0.24

30

0.45

200

0.12

0.80

500

0.19

40

0.35

125

0.14

0.70

400

0.18

104

°

F (40

°

C)

10

1.00

640

0.23

20

0.70

400

0.16

1.15

640

0.22

30

0.50

250

0.15

0.95

640

0.25

40

0.45

200

0.13

0.80

500

0.21

KODAK VERSAMAT 641 Chemicals, Model 1140

Machine

Speed

(fpm)

1 Developer Rack

2 Developer Racks

Average

Gamma

ISO A D-min

Average

Gamma

ISO A D-min

99

°

F (37

°

C)

10

0.80

400

0.17

1.15

640

0.19

104

°

F (40

°

C)

10

0.85

320

0.16

1.30

800

0.21

20

0.55

160

0.22

0.90

500

0.21