CHARGING THE Li-ion BATTERY PACK

The Li-ion battery pack can be charged after it has
been installed onto the transceiver. The battery pack
is provided uncharged for safety purposes.

1 Confirm that the transceiver power is OFF.

•

While charging the battery pack, leave the
transceiver power OFF.

2 Insert the charger plug into the DC IN jack of the

transceiver.

3 Plug the charger into an AC wall outlet.

•

Charging starts and 2 LEDs on the top panel
lights orange.

4 It takes approximately 6.5 hours to charge an

empty PB-42L Li-ion battery pack. When charging
completes, the LEDs unlight; remove the charger
plug from the transceiver DC IN jack.

5 Unplug the charger from the AC wall outlet.

Note:

◆

If you turn the transceiver ON and press [F], [LOW/ BATT] while
charging the battery pack, “CHARGING” appears. “STANDBY”
appears when the charging completes.

◆

The transceiver becomes warm while charging the battery pack.

◆

If the charger plug is plugged into the DC IN jack before the
battery pack is attached, turn the transceiver ON and then OFF
again to initiate the charging.

◆

Exceeding the specified charge period shortens the useful
life of the Li-ion battery pack.

◆

The provided charger is designed to charge only the
provided PB-42L Li-ion battery pack. Charging other models
of battery packs may damage the charger and battery pack.

◆

Do not press [PTT] while charging.

◆

The battery pack must be kept in cool and dry place.

◆

Never leave the battery pack in the direct sun light.

CONNECTING TO A CIGARETTE LIGHTER
SOCKET

To connect the transceiver to the cigarette lighter
socket in your vehicle, use an optional PG-3J
Cigarette Lighter cable.

While the PG-3J is connected to the cigarette lighter
plug, the transceiver automatically start charging the
Li-ion battery pack (PB-42L). When you operate the
transceiver, it charges the Li-ion battery pack in back

ground. If the transceiver is turned OFF, the 2 LEDs
light orange while charging. When the charging
completes, they turn OFF {above}.

To connect with an external 24 V power source via a DC-DC
converter, only use the optional PG-3J Cigarette Lighter cable.
Using the PG-2W DC cable in this situation may cause a fire.

PG-2W

2 4 V

1 2 V

2 4 V

PG-3J

1 2 V

1 2 V

2 4 V

PG-3J

Note: If the input voltage exceeds approximately 16.5 V, warning
beeps sound and “VOLTAGE ERROR” appears.

CONNECTING TO A REGULATED POWER
SUPPLY

To connect the transceiver to an appropriate
regulated power supply, use an optional PG-2W
DC cable.

1 Confirm that the power of both the transceiver and

the power supply are OFF.

2 Connect the optional PG-2W DC cable to the

power supply; the red lead to the positive (+)
terminal, and the black lead to the negative (–)
terminal.

3 Connect the barrel plug on the DC cable to

the DC IN jack of the transceiver.

If the transceiver is turned OFF while a regulated
power supply is connected with the DC IN jack, it
automatically initiates charging the Li-ion battery pack
(PB-42L) {above}.

Note:

◆

If the DC power supply voltage is below 12.0 V DC, you may not
be able to charge the Li-ion battery pack (PB-42L).

◆

The supply voltage must be between 12.0 V and 16.0 V to
prevent damaging the transceiver. If input voltage exceeds
approximately 16.5 V, warning beeps sound and “VOLTAGE
ERROR” appears. Remove the DC IN jack plug immediately.

◆

If the DC power supply voltage is above 14.5 V DC and “H” (High
Power) is selected, “H” icon blinks and the output power is
reduced to “L” level (Low Power) automatically {page 41}.

DC IN jack

DC 12 V

DC-DC Converter

DC-DC Converter

Fuses (4 A)

DC IN jack

DC IN jack