SERVICE TECH INFORMATION

SECTION 5

21

5A.

TROUBLESHOOTING

AUTOMATIC ELECTRONIC DIAGNOSTICS

The face plate computer has a self-diagnostic

function for the electrical system (except input

power and water meter). The

computer monitors the elec-

tronic components and circuits

for correct operation. If a

malfunction occurs, an error

code appears in the face plate

display.

The chart below shows the error codes that could

appear, and the possible defects for each code.

While an error code appears in the display, all face

plate buttons are inoperable except the SELECT

button. SELECT remains operational so the service

person can make the MANUAL INITIATED

ELECTRONIC DIAGNOSTICS (below) to further

isolate the defect, and check the water meter.

CODE

POSSIBLE DEFECT

MOST LIKELY

LESS LIKELY

Err1

motor inop. / wiring harness or connection to switch / position switch / face plate

Err2

face plate

Err3

motor / face plate

See face plate replacement on

page 22.

Err4

face plate / position switch

See face plate replacement on

page 22.

Err5

face plate

PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE: 1. Unplug transformer 2. Correct defect

3. Plug in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.

MANUAL INITIATED ELECTRONICS DIAG-

NOSTICS

1.

To enter diagnostics¼

----from a error code display, press the #1

SELECT button.

----from a time display, press and hold the #1

SELECT button for 3 seconds.

You will see 1 of the following displays.

All of the preceeding displays show what position

the valve is in, if the turbine is operating, and the

position switch open or closed status.

2.

Press the ON/OFF-HOLD button to advance

the valve to the next position. To verify

component operation, or to possibly isolate a

defect, observe the following.

POSITION SWITCH STATUS: WIth the valve in

service, or any of the recharge cycles, the switch

indicator will show open

. While the valve is

rotating from 1 position to another, the indicator

will show the switch closed

. A defect is

probable if indications vary from this pattern.