Do not connect the receiver directly to the vehicle’s battery
without following these additional steps:

• Install a protective fuse (6 amps) within 18" of the battery.

• Install a relay, switched from the ignition, between the battery and

the receiver.

• Use fire-resistant AWG 8 wire from the relay to the battery.

Connecting to Power (cont’d)

Effective April 2004
Subject to change without notice

VEHICLE POWER

(10-16 VDC)

VHF

ANTENNA IN

S-VIDEO

TO KVH

ANTENNA

TO VIDEO

SATELLITE IN

AUDIO R

AUDIO L

VIDEO

RF REMOTE

INPUT

OUT TO TV

COMPOSITE VIDEO

TO IRD

SATELLITE IN

DIAGNOSTIC PORT 1

DIAGNOSTIC PORT 2

Ground

Fuse

(6 Amp)

Vehicle
Battery

+12 VDC

Ground

Switched

Relay

Ground

Ignition

Ground

AWG 8

Wire

Pillar Ground Screw

+

TracVision A5 Receiver

Fuse

(6 Amp)

Supplied Cable