Connecting to power (cont’d), Installation, 6 amp) – KVH Industries KVH TracVision User Manual
Page 9

Installation
54-0239
TracVision A5 Shop Manual
© 2004 KVH Industries, Inc., All rights reserved.
Do not connect the receiver directly to the vehicle’s battery
without following these additional steps:
• Install a protective fuse (6 amps) within 18" of the battery.
• Install a relay, switched from the ignition, between the battery and
the receiver.
• Use fire-resistant AWG 8 wire from the relay to the battery.
Connecting to Power (cont’d)
Effective April 2004
Subject to change without notice
VEHICLE POWER
(10-16 VDC)
VHF
ANTENNA IN
S-VIDEO
TO KVH
ANTENNA
TO VIDEO
SATELLITE IN
AUDIO R
AUDIO L
VIDEO
RF REMOTE
INPUT
OUT TO TV
COMPOSITE VIDEO
TO IRD
SATELLITE IN
DIAGNOSTIC PORT 1
DIAGNOSTIC PORT 2
Ground
Fuse
(6 Amp)
Vehicle
Battery
+12 VDC
Ground
Switched
Relay
Ground
Ignition
Ground
AWG 8
Wire
Pillar Ground Screw
+
–
TracVision A5 Receiver
Fuse
(6 Amp)
Supplied Cable