Connect power, Connect power, 14, Connect power 12 – KVH Industries TracVision M5 User Manual

Page 14

Advertising
background image

14

Follow these steps to connect power. The
switchplate supplies power to both the antenna
and the MCP.

a. Before you begin, disconnect vessel power.

b. Route a set of power wires from the

switchplate’s power output terminals to the

MCP (for cable specifications, see Figure 2 on

page 3). Connect the wires to the plastic

power plug supplied in the kitpack (see

Figure 27).

NOTE: You should now have three wires
connected to each power output terminal on the
switchplate: one set of wires to power the antenna,
one set to power the MCP, and one set to power
the switchplate’s indicator lamp (installed at the
factory).

c. Tighten the terminal screws on the

switchplate to secure all wires in place.

d. Plug the MCP power plug into the “Power

In” jack on the MCP (see Figure 28). Secure in

place with the retaining screws.

e. Connect a power cable to 12 VDC vessel

power (for cable specifications, see Figure 2
on page 2).

f. Connect your vessel power wires to the

power (+) and ground (-) input terminals on

the switchplate (see Figure 29).

CAUTION

For your own safety, disconnect vessel power

and make sure the circuit is dead before you

connect any power wires.

Figure 27: MCP Power Plug

Terminal Screw (x2)

Ground

Power

Retaining Screw (x2)

HDTV

CONTROL

ANTENNA UNIT

RF PORT

TONE

DETECT

FUSE

POWER IN

+ / –

Switchplate-to-MCP
Power Cable

MCP

+ –

+

Figure 28: MCP Power Wiring

Power supplied to the antenna must not fall

below 11 VDC or exceed 16 VDC.

IMPORTANT!

11-16 VDC

Ground

Vessel Power

+

Figure 29: Switchplate Wiring - Vessel Power Cable

Connect Power

12

Advertising